DENNISON DIV AVERY-DENNISON INC -- STAMP PAD INKS, 0023 -- 7510-00N056932
===================== Product Identification =====================
Product ID:STAMP PAD INKS, 0023
MSDS Date:07/30/1993
FSC:7510
NIIN:00N056932
=== Responsible Party ===
Company Name:DENNISON DIV AVERY-DENNISON INC
Address:1 CLARK HILL
City:FRAMINGHAM
State:MA
ZIP:01701
Country:US
Info Phone Num:508-879-4636
Emergency Phone Num:508-879-0511
CAGE:IO965
=== Contractor Identification ===
Company Name:DENNISON DIV AVERY-DENNISON INC
Address:1 CLARK HILL
Box:City:FRAMINGHAM
State:MA
ZIP:01701
Country:US
Phone:508-879-4636
CAGE:IO965
Company Name:DENNISON MFG CO IDENTIFICATION SYSTEMS DIV
Address:300 HOWARD STREET
Box:City:FRAMINGHAM
State:MA
ZIP:01701-8832
Country:US
Phone:508-879-0511
CAGE:16956
============= Composition/Information on Ingredients =============
Ingred Name:ETHYLENE GLYCOL (SARA 313) (CERCLA)
CAS:107-21-1
RTECS #:KW2975000
OSHA PEL:50 PPM (MFR)
ACGIH TLV:50 PPM, VAPOR, C
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:NO SYMPTOMS EXPECTED. EYE
CONTACT:MAY CAUSE IRRITATION. SKIN ABSORPTION:NO EVIDENCE OF
HARMFUL EFFECTS. INGEST:MAY CAUSE ABDOMINAL DISCOMFORT OR PAIN,
NAUSEA, VOMITING, DIZZINESS, DROWSINESS, CE NTRAL NERVOUS SYSTEM
EFFECTS.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:EYE:FLUSH W/LARGE AMOUNTS OF WATER FOR AT LEAST 15 MINUTES,
IF IRRITATION OCCURS, GET MEDICAL ATTENTION. SKIN:THOROUGHLY WASH
W/SOAP & WATER. INHAL:REMOVE TO FRESH AIR, OBTAIN MEDICAL ATTENTION
IF SYM PTOMS PERSIST. INGEST:IF CONSCIOUS, GIVE TWO GLASSES OF
WATER, INDUCE VOMITING & OBTAIN MEDICAL ATTENTION W/OUT DELAY.
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:225F,107C
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . USE WATER SPRAY TO COOL NEARBY CONTAINERS.
Unusual Fire/Explosion Hazard:NONE.
================== Accidental Release Measures ==================
Spill Release Procedures:ABSORB LIQUID ON PAPER OR OTHER ABSORBENT
MATERIAL, FLUSH W/WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Other Precautions:A FINISHED STAMP PAD CONTAINS A SUBSTANTIALLY LOWER
PERCENTAGE BY WEIGHT OF EACH CHEMICAL & HAS INK HELD W/IN ABSORBENT
MATERIAL.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED SAFETY GLASSES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:OBSERVE ORDINARY MEASURES OF PERSONAL HYGIENE.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:365F,185C
Vapor Pres:0.22 @ 20C
Spec Gravity:1.04
Evaporation Rate & Reference:<0.01 (BUTYL ACETATE=1)
Solubility in Water:COMPLETE
Appearance and Odor:LIQUID-COLORED; MILD ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Hazardous Decomposition Products:MAY FORM TOXIC MATERIALS, CARBON
DIOXIDE OR CARBON MONOXIDE.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF I/A/W LOCAL, STATE & FEDERAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.