EASTMAN KODAK COMPANY -- 169 1757,PT B,TONING BATH,KODAK SEPIA TONER -- 6750-00-110-8067
===================== Product Identification =====================
Product ID:169 1757,PT B,TONING BATH,KODAK SEPIA TONER
MSDS Date:02/28/2000
FSC:6750
NIIN:00-110-8067
Status Code:A
Kit Part:Y
=== Responsible Party ===
Company Name:EASTMAN KODAK COMPANY
Address:343 STATE STREET
City:ROCHESTER
State:NY
ZIP:14650
Country:US
Info Phone Num:716-722-5151/(800) 242-2424
Emergency Phone Num:716 722-5151
Preparer's Name:NOT PROVIDED
CAGE:19139
=== Contractor Identification ===
Company Name:EASTMAN KODAK CO GOVERNMENT MARKETS CONTRACTS
Address:343 STATE ST
Box:City:ROCHESTER
State:NY
ZIP:14650-1115
Country:US
Phone:716-722-5151/(800) 242-2424
CAGE:19139
============= Composition/Information on Ingredients =============
Ingred Name:SODIUM SULFIDE
CAS:1313-82-2
RTECS #:WE1905000
Minumum % Wt:60.
Maxumum % Wt:65.
Ingred Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Minumum % Wt:35.
Maxumum % Wt:40.
===================== Hazards Identification =====================
LD50 LC50 Mixture:ORAL LD-50 (RAT): 100-200 MG/KG
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EFFECTS OF EXPOSURE: INHALATION:
HARMFUL IF INHALED. AIRBORNE DUST IRRITATING. IF HYDROGEN SULFIDE
GAS IS LIBERATED DUE TO CONTACT WITH ACID, IT MAY CAUSE HEADACHE,
NAUSEA, DIZZINESS, CONFUSION, WEAKN ESS, UNCONSCIOUSNESS,
CONVULSIONS AND DEATH. EYES: CAUSES BURNS. SKIN: CAUSES BURNS.
INGESTION: HARMFUL IF SWALLOWED. MAY CAUSE BURNS OF THE
GASTROINTESTINAL TRACT IF SWALLOWED. IF FREE GASTRIC ACID ITY IS
HIGH, HYDROGEN SULFIDE IS LIBERATED IN THE STOMACH AND MAY CAUSE
SYSTEMIC TOXIC EFFECTS SUCH AS VOMITING, RESPIRATORY DEPRESSION,
TREMORS, CONVULSIONS AND DEATH.
Explanation of Carcinogenicity:CARCINOGENICITY CLASSIFICATION
(COMPONENTS PRESENT AT 0.1% OR MORE): - INTERNATIONAL AGENCY FOR
RESEARCH ON CANCER (IARC): NONE - AMERICAN CONFERENCE OF
GOVERNMENTAL INDUSTRIAL HYGIENISTS (ACGIH): NON E - NATIONAL
TOXICOLOGY PROGRAM (NTP): NONE - OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION (OSHA): NONE
Effects of Overexposure:INHALATION: AIRBORNE DUST IRRITATING. IF
HYDROGEN SULFIDE GAS IS LIBERATED DUE TO CONTACT WITH ACID, IT MAY
CAUSE HEADACHE, NAUSEA, DIZZINESS, CONFUSION, WEAKNESS,
UNCONSCIOUSNESS, CONVULSIONS AND DEA TH. EYES: CAUSES BURNS. SKIN:
CAUSES BURNS. INGESTION: MAY CAUSE BURNS OF THE GASTROINTESTINAL
TRACT IF SWALLOWED. IF FREE GASTRIC ACIDITY IS HIGH, HYDROGEN
SULFIDE IS LIBERATED IN THE STOMACH AND MAY CAUSE SYSTEMIC TOXIC
EFFECTS SUCH AS VOMITING, RESPIRATORY DEPRESSION, TREMORS,
CONVULSIONS AND DEATH.
Medical Cond Aggravated by Exposure:NOT PROVIDED
======================= First Aid Measures =======================
First Aid:INHALATION: MOVE TO FRESH AIR. GET MEDICAL ATTENTION. EYES:
IMMEDIATELY FLUSH WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES. GET
MEDICAL ATTENTION IMMEDIATELY. SKIN: IMMEDIATELY FLUSH WITH PLENTY
OF WA TER FOR AT LEAST 15 MINUTES WHILE REMOVING CONTAMINATED
CLOTHING AND SHOES. GET MEDICAL ATTENTION. WASH CONTAMINATED
CLOTHING BEFORE REUSE. INGESTION: DO NOT INDUCE VOMITING.
GIVE VICTIM A GLAS S OF WATER. NEVER GIVE ANYTHING BY MOUTH TO AN
UNCONSCIOUS PERSON. CALL A PHYSICIAN OR POISON CONTROL CENTER
IMMEDIATELY.
===================== Fire Fighting Measures =====================
Flash Point:NONE
Extinguishing Media:WATER SPRAY, CARBON DIOXIDE (CO2), DRY CHEMICAL
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING. FIRE OR EXCESSIVE HEAT MAY PRODUCE HAZARDOUS
DECOMPOSITION PRODUCTS.
Unusual Fire/Explosion Hazard:POWDERED MATERIAL MAY FORM EXPLOSIVE
DUST-AIR MIXTURES.
================== Accidental Release Measures ==================
Spill Release Procedures:COLLECT UP AND PUT IN A SUITABLE CONTAINER.
AVOID GENERATION OF DUST. CLEAN SURFACE THOROUGHLY TO REMOVE
RESIDUAL CONTAMINATION.
Neutralizing Agent:NOT PROVIDED
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP CONTAINER TIGHTLY CLOSED. KEEP
FROM CONTACT WITH OXIDIZING MATERIALS. KEEP AWAY FROM INCOMPATIBLE
SUBSTANCES. POWDERED MATERIAL MAY FORM EXPLOSIVE DUST-AIR MIXTURES.
MINIMIZE DUST GENERATION AND ACCUMULATION. KEEP AWAY FROM SOURCES
OF IGNITION. KEEP FROM CONTACT WITH OXIDIZING MATERIALS.
Other Precautions:AVOID BREATHING DUST. DO NOT GET IN EYES, ON SKIN, ON
CLOTHING. USE WITH ADEQUATE VENTILATION. WASH THOROUGHLY AFTER
HANDLING. KEEP AWAY FROM INCOMPATIBLE SUBSTANCES. REFER TO NFPA
PAMPHLET NO. 654, " PREVENTION OF FIRE AND DUST EXPLOSIONS IN THE
CHEMICAL, DYE, PHARMACEUTICAL, AND PLASTICS INDUSTRIES ."
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IF ENGINEERING CONTROLS DO NOT MAINTAIN AIRBORNE
CONCENTRATIONS TO AN ACCEPTABLE LEVEL, AN APPROVED RESPIRATOR MUST
BE WORN. RESPIRATOR TYPE: DUST. A FULL-FACE POSITIVE-PRESSURE
AIR-SUPPLIED RESPIRATO R MUST BE WORN IF HAZARDOUS DECOMPOSITION
PRODUCTS ARE LIKELY TO BE RELEASED OR HAVE BEEN RELEASED. OBSERVE
OSHA STANDARD 29 CFR 1910.134.
Ventilation:GOOD GENERAL VENTILATION (TYPICALLY 10 AIR CHANGES PER
HOUR) SHOULD BE USED. VENTILATION RATES SHOULD BE MATCHED TO
CONDITIONS.
Protective Gloves:WEAR IMPERVIOUS GLOVES AND PROTECTIVE CLOTHING
APPROPRIATE FOR RISK OF EXPOSURE
Eye Protection:WEAR SAFETY GLASSES WITH SIDE SHIELDS (OR GOGGLES) AND A
FACE SHIELD.
Other Protective Equipment:EYE BATH, SAFETY SHOWER, WASHING FACILITIES
Work Hygienic Practices:NOT PROVIDED
Supplemental Safety and Health
USE PROCESS ENCLOSURES, LOCAL EXHAUST VENTILATION OR OTHER ENGINEERING
CONTROLS TO MAINTAIN AIRBORNE LEVELS TO AN ACCEPTABLE LEVEL.
ABBREVIATION: N/A=NOT APPLICABLE OR NOT AVAILABLE. N/K=UNKNOWN. N/P
=NOT PROVIDED. N/R=NOT RELEVANT. N/D=NOT DETERMINED. N/E=NOT
ESTABLISHED.
================== Physical/Chemical Properties ==================
HCC:B1
NRC/State Lic Num:NOT RELEVANT
Boiling Pt:=145.C, 293.F
Melt/Freeze Pt:=90.6C, 195.F
Decomp Temp:Decomp Text:NOT PROVIDED
Vapor Pres:NEGLIGIBLE
Spec Gravity:1.69
Solubility in Water:APPRECIABLE
Appearance and Odor:LIGHT YELLOW SOLID (FLAKE). ODOR: PUNGENT
Percent Volatiles by Volume:NEGLIGIBLE
Corrosion Rate:NOT PROVIDED
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG ACIDS. CONTACT WITH ACID LIBERATES
FLAMMABLE MATERIAL, POISONOUS GAS.
Stability Condition to Avoid:NOT PROVIDED
Hazardous Decomposition Products:HYDROGEN SULFIDE, OXIDES OF SULFUR.
=================== Toxicological Information ===================
Toxicological Information:EFFECTS OF EXPOSURE: INHALATION: HARMFUL IF
INHALED. AIRBORNE DUST IRRITATING. IF HYDROGEN SULFIDE GAS IS
LIBERATED DUE TO CONTACT WITH ACID, IT MAY CAUSE HEADACHE, NAUSEA,
DIZZINESS, CONFUSION, WEAKN ESS, UNCONSCIOUSNESS, CONVULSIONS AND
DEATH. EYES: CAUSES BURNS. SKIN: CAUSES BURNS. INGESTION: HARMFUL
IF SWALLOWED. MAY CAUSE BURNS OF THE GASTROINTESTINAL TRACT IF
SWALLOWED. IF FREE GASTRIC ACID ITY IS HIGH, HYDROGEN SULFIDE IS
LIBERATED IN THE STOMACH AND MAY CAUSE SYSTEMIC TOXIC EFFECTS SUCH
AS VOMITING, RESPIRATORY DEPRESSION, TREMORS, CONVULSIONS AND
DEATH. ORAL LD-50 (RAT): 100-200 MG/K G. DERMAL LD-50: < 340 MG/KG
===================== Ecological Information =====================
Ecological:THE FOLLOWING PROPERTIES ARE ESTIMATED FROM THE COMPONENTS
OF THE PREPARATIONS. POTENTIAL TOXICITY: FISH LC50 MG/L: 1-10.
DAPHNID EC50 MG/L: 10-100. ALGAL IC50 MG/L: >100. ORGANICS
READILY DEGR ADABLE (>70%): NOT APPLICABLE. POTENTIAL
BIOACCUMULATION: LOG POW <1. COD (APPROXIMATE G/L): NOT PROVIDED.
BOD5 (APPROXIMATE G/L): NOT AVAILABLE. POTENTIAL TOXICITY: WASTE
TREATMENT MICROORGANISM S EC50 (MG/L): NOT AVAILABLE.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISCHARGE, TREATMENT, OR DISPOSAL MAY BE SUBJECT
TO NATIONAL, STATE, OR LOCAL LAWS. SINCE EMPTIED CONTAINERS RETAIN
PRODUCT RESIDUE, FOLLOW LABEL WARNINGS EVEN AFTER CONTAINER IS
EMPTIED. CONTRACT WIT H A LICENSED CHEMICAL DISPOSAL AGENCY.
=================== MSDS Transport Information ===================
Transport Information:FOR TRANSPORTATION INFORMATION REGARDING THIS
PRODUCT CALL THE KODAK WORLDWIDE TRANSPORTATION HAZMAT HOT LINE:
(716) 722-2400 BETWEEN 8 A.M. AND 5 P.M. (EASTERN STANDARD TIME),
MONDAY THROUGH FRIDAY .
===================== Regulatory Information =====================
SARA Title III Information:CHEMICAL(S) SUBJECT TO THE REPORTING
REQUIREMENTS OF SECTION 313 OR TITLE III OF THE SUPERFUND
AMENDMENTS AND REAUTHORIZATION ACT (SARA) OF 1986 AND 40 CFR
PART 372: NONE
Federal Regulatory Information:NOT PROVIDED
State Regulatory Information:MATERIAL(S) KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE CANCER: NONE - MATERIAL(S) KNOWN TO THE STATE
OF CALIFORNIA TO CAUSE ADVERSE REPRODUCTIVE EFFECTS: NONE
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.