E I DUPONT DE NEMOURS & CO INC -- SUVA 95 -- 6830-00N082087
===================== Product Identification =====================
Product ID:SUVA 95
MSDS Date:04/05/1995
FSC:6830
NIIN:00N082087
=== Responsible Party ===
Company Name:E I DUPONT DE NEMOURS & CO INC
Address:1007 MARKET ST
City:WILMINGTON
State:DE
ZIP:19898
Country:US
Info Phone Num:800-441-7515
Emergency Phone Num:800-441-3637;800-424-9300(CHEMTREC)
CAGE:0ERJ7
=== Contractor Identification ===
Company Name:E I DUPONT DE NEMOURS & CO, INC.
Address:1007 MARKET STREET
City:WILMINGTON
State:DE
ZIP:19898
Country:US
Phone:800-441-7515
CAGE:0ERJ7
Company Name:E.I. DUPONT DE NEMOURS & CO
Address:1007 MARKET STREET
Box:City:WILMINGTON
State:DE
ZIP:19898
Country:US
Phone:800-441-7515;800-441-9442
CAGE:18873
============= Composition/Information on Ingredients =============
Ingred Name:METHANE, TRIFLUORO-; (TRIFLUOROMETHANE)
CAS:75-46-7
RTECS #:PB6900000
Fraction by Wt: 30-50%
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:ETHANE, HEXAFLUORO-; (HEXAFLUOROETHANE)
CAS:76-16-4
RTECS #:KI4110000
Fraction by Wt: 50-70%
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:SUP DAT: & CREATININE, REVERSIBLE PATHOLOGICAL CHANGES IN
KIDNEYS, & INCRD URINARY FLUORIDE CONC. ONE STUDY (ING 4)
RTECS #:9999999ZZ
Ingred Name:ING 3: SHOWED SOME ARRHYTHMOGENIC EFTS IN BOTH GUINEA PIGS
& DOGS. LONG-TERM INHAL EXPOS RESULTED IN INITIAL (ING 5)
RTECS #:9999999ZZ
Ingred Name:ING 4: DECREASE IN GROWTH RATE, BUT NO OTHER ADVERSE
CHANGES WERE NOTED.
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL OF HIGH CONCS OF VAP IS
HARMFUL & MAY CAUSE HEART IRREGULARITIES, UNCON/DEATH. INTENTIONAL
MISUSE CAN BE FATAL. VAP REDUCES OXYGEN AVAIL FOR BRTHG & IS
HVR/AIR. LIQ CONT CAN CAUSE FROSTBI TE. HUMAN HLTH EFTS OF OVEREXP
BY INHALMAY INCL NONSPECIFIC DISCOMFORT SUCH AS NAUS, HDCH/WEAK;
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: TEMPORARY NERV SYS DEPRESS W/ANESTH
EFTS SUCH AS DIZZ, HDCH, CONFUSION, INCOORD, & LOSS OF
CONSCIOUSNESS; OR W/GROSS OVEREXP, POSS TEMPORARY ALTERATION OF
HEART'S ELEC ACTIVITY W/IRREG PULSE , PALPITATIONS/INADEQ
CIRCULATION. EYE/SKIN CONT W/LIQ MAY CAUSE FROSTBITE. TOX INFO:
ANIMAL DATA: ING 1: (SUP DAT)
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH PREEXISTING
DISEASES OF THE CENTRAL NERVOUS OR CARDIOVASCULAR SYSTEM MAY HAVE
INCREASED SUSCEPTIBILITY TO THE TOXICITY OF EXCESSIVE EXPOSURES.
======================= First Aid Measures =======================
First Aid:INHAL: IMMED REMOVE TO FRESH AIR. KEEP PERS CALM. CALL MD. IF
NOT BRTHG, GIVE ARTF RESP. IF BRTHG IS DFCLT, GIVE OXYGEN. SKIN:
FLUSH W/WATER. TREAT FOR FROSTBITE IF NEC. EYES: FLUSH W/WATER FOR
AT LEA ST 15 MIN. CALL MD IF FROSTBITE OCCURS.INGEST: CALL MD IMMED
. NOTES TO MD: BECAUSE OF POSS DISTURBS OF CARD RHYTHM,
CATECHOLAMINE DRUGS, SUCH AS EPINEPHRINE, SHOULD BE CONSIDERED (SUP
DAT)
===================== Fire Fighting Measures =====================
Extinguishing Media:USE MEDIA APPROPRIATE FOR SURROUNDING MATERIAL.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT . USE WATER SPRAY OR FOG TO COOL CONTAINERS.
Unusual Fire/Explosion Hazard:CYLS ARE EQUIPPED W/TEMP & PRESS RELIEF
DEVICES BUT MAY STILL RUPTURE UNDER FIRE CNDTNS. DECOMP MAY OCCUR,
PRODUCING HF, CARBON MONOXIDE & POSSIBLY COF*2.
================== Accidental Release Measures ==================
Spill Release Procedures:REVIEW FIRE FIGHT MEASURES & HNDLG (PERS)
SECTIONS BEFORE PROCEEDING W/CLEAN-UP. USE APPROP PERS PROT EQUIP
DURING CLEAN-UP. MATL EVAPORATES AT ATM PRESS (VAPORIZES). VENT
AREA - ESP LOW PLACES WHERE HEAVY VAPS MAY COLLECT. REMOVE OPEN
FLAMES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID CONTACT OF LIQUID WITH EYES AND
PROLONGED SKIN EXPOSURE. USE WITH SUFFICIENT VENTILATION TO KEEP
EMPLOYEE EXPOSURE BELOW RECOMMENDED LIMITS.
Other Precautions:STORE IN CLEAN, DRY AREA. DO NOT HEAT ABOVE 51.7C
(125F).
============= Exposure Controls/Personal Protection =============
Respiratory Protection:UNDER NORMAL MANUFACTURING CONDITIONS, NO
RESPIRATORY PROTECTION IS REQUIRED WHEN USING THIS PRODUCT. NIOSH
APPROVED SCBA IS REQUIRED IF A LARGE SPILL OR RELEASE OCCURS.
Ventilation:NORM VENT FOR STANDARD MFG PROC GEN ADEQ. USE LOC EXHAUST
WHEN LARGE AMOUNTS ARE RELEASED. USE MECH VENT IN LOW PLACES.
Protective Gloves:NEOPRENE RUBBER OR LEATHER GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRST AID PROC: ONLY AS A LAST RESORT IN LIFE-THREATENING EMERGENCIES.
EFTS OF OVEREXP: TOX EFTS DESCRIBED IN ANIMALS FROM EXPOS BY INHAL
INCL ANESTH EFTS & NONSPECIFIC EFTS SUCH AS WT LOSS AT CONCS > 22%.
ING 2: EFTS OBSERVED IN ANIMALS BYINHAL INCL DECRD GROWTH RATE,
PULM CHANGES, IRREG RESP, INCRD URINE VOL (ING 3)
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:-126F,-88C
Appearance and Odor:CLEAR, COLORLESS COMPRESSED GAS; SLIGHT ETHEREAL
ODOR
Percent Volatiles by Volume:100 WT
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NO DATA AVAILABLE.
Stability Condition to Avoid:AVOID OPEN FLAMES AND HIGH TEMPERATURES.
Hazardous Decomposition Products:THIS PRODUCT CAN BE DECOMPOSED BY HIGH
TEMPERATURES (OPEN FLAMES, GLOWING METAL SURFACES, ETC) FORMING HF,
COF*2, OR CO.
==================== Disposal Considerations ====================
Waste Disposal Methods:RECLAIM BY DISTILLATION OR REMOVE TO A PERMITTED
WASTE DISPOSAL FACILITY. DISPOSE IN ACCORDANCE WITH ALL FEDERAL,
STATE AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.