HARBORLITE CORP -- PERLITE -- 6850-00N020486
===================== Product Identification =====================
Product ID:PERLITE
MSDS Date:04/07/1989
FSC:6850
NIIN:00N020486
=== Responsible Party ===
Company Name:HARBORLITE CORP
Address:1450 SIMPSON WAY
City:ESCONDIDO
State:CA
ZIP:92025
Country:US
Info Phone Num:619-745-5900
Emergency Phone Num:619-745-5900
CAGE:HARB0
=== Contractor Identification ===
Company Name:HARBORLITE CORP
Address:1450 SIMPSON WAY
Box:City:ESCONDIDO
State:CA
ZIP:92025
Country:US
Phone:619-745-5900
CAGE:HARB0
============= Composition/Information on Ingredients =============
Ingred Name:PERLITE (EXPANDED FORM)
CAS:93763-70-3
RTECS #:SD5254000
OSHA PEL:5 MG/M3 (RDUST)
ACGIH TLV:10 MG/M3 (TDUST)
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:(ACUTE & CHRONIC) NONE. INNOCUOUS
DUST, CHEMICALLY INERT, NON-CARCINOGENIC, NON-CRYSTALLINE. NO KNOWN
ADVERSE EFFECTS OF OVEREXPOSURE.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:NONE
Medical Cond Aggravated by Exposure:NONE
======================= First Aid Measures =======================
First Aid:NO EMERGENCY FIRST AID PROCEDURES REQUIRED. AS WITH ANY
NUISANCE DUST, EYE DISCOMFORT FROM INJECTION OR ACCRETION UNDER LID
MAY BE EASED BY EYE WASH. INGEST: CALL MD IMMEDIATELY . INHAL:
REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O2/ARTIFICIAL
RESPIRATION) . SKIN: FLUSH WITH COPIOUS AMOUNTS OF WATER. CALL MD .
===================== Fire Fighting Measures =====================
Flash Point:NONE
Extinguishing Media:MATERIAL DOES NOT BURN. IS WATER, DRY CHEMICAL, CO2
COMPATIBLE.
Fire Fighting Procedures:WILL NOT BURN NOR SUPPORT COMBUST.CRUDE
PERLITE EXPANDS&CHANGES FROM GRAY TO WHITE IN COLOR @ APPROX
1800F.WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
Unusual Fire/Explosion Hazard:NONE. THIS MATERIAL IS USED COMMERCIALLY
FOR FIRE PROOFING AND INSULATION.
================== Accidental Release Measures ==================
Spill Release Procedures:SWEEP INTO CONTAINER AND DISCARD. THIS IS AN
INNOCUOUS WHITE, INERT MINERAL POWDER. IT IS NOT HARMFUL TO TOUCH
OR HANDLE. REPORTABLE QTY IN CASE OF SPILLAGE: HARBORLITE
FILTERAIDS HAVE NO "RQ FILTER".
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:MATERIAL IS EASILY SUSPENDED IN AIR IN
WINDY CONDITIONS.
Other Precautions:IN WINDY CONDITIONS EYE GOGGLES MAY BE DESIRABLE FOR
OPERATOR COMFORT.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPROVED MSA DUSTFOE 77.
Ventilation:LOCAL EXHAUST: TO MINIMIZE NUISANCE DUST. MECHANICAL
(GENERAL): DUMP STATION.
Protective Gloves:NONE REQUIRED.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE
Work Hygienic Practices:ROUTINE HOUSEKEEPING PRACTICES ARE SUFFICIENT
TO HANDLE ANY APPLICATION OF HARBORLITE FILTERAIDS.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
================== Physical/Chemical Properties ==================
HCC:N1
Melt/Freeze Pt:M.P/F.P Text:2192F,1200C
Spec Gravity:0.17
Solubility in Water:INSOLUBLE
Appearance and Odor:WHITE AND LIGHT WEIGHT. NO ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
IN HYDROFLORIC ACID WILL PARTIALLY DISSOLVE.
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:NONE
==================== Disposal Considerations ====================
Waste Disposal Methods:DISCARD IN ANY TRASH DISPOSAL/LANDFILL FACILITY.
NO SPECIAL PRECAUTIONS OR PROCEDURES. DISPOSAL MUST BE IN
ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.