E.I.DUPONT DE NEMOURS & CO. -- FREON 500 REFRIGERANT (DU001075) -- 6830-00-089-0697
=====================  Product Identification  =====================

Product ID:FREON 500 REFRIGERANT (DU001075)
MSDS Date:06/10/1991
FSC:6830
NIIN:00-089-0697
=== Responsible Party ===
Company Name:E.I.DUPONT DE NEMOURS & CO.
Address:CHESTNUT RUN
Box:80709
City:WILMINGTON
State:DE
ZIP:19898
Info Phone Num:302-774-2421
Emergency Phone Num:302-774-2421
Preparer's Name:W. J. BROCK
CAGE:DO229
=== Contractor Identification ===
Company Name:DU PONT E I  DE NEMOURS AND CO INC   PETROCHEMICALS DEPT
Address:1251 BRANDYWINE BLDG
Box:City:WILMINGTON
State:DE
ZIP:19898
Phone:302-773-5676
CAGE:73925
Company Name:E.I.DUPONT DE NEMOURS & CO INC
Address:549 ALBANY STREET
Box:1635
City:BOSTON
State:MA
ZIP:02118
Phone:800-441-7515
CAGE:DO229

=============  Composition/Information on Ingredients  =============

Ingred Name:DICHLORODIFLUOROMETHANE (SARA III) (AUTOIGNIT = <1400F)
CAS:75-71-8
RTECS #:PA8200000
Fraction by Wt: 73.8%
OSHA PEL:1000 PPM 8 HR TWA
ACGIH TLV:1000 PPM 8 HR TWA
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ozone Depleting Chemical:1

Ingred Name:DIFLUOROETHANE (AUTOIGNIT = <836F)
CAS:75-37-6
RTECS #:KI1410000
Fraction by Wt: 26.2%
Other REC Limits:1000PPM 8HR TWA, MFG
OSHA PEL:NOT EST.

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:SEE SUPLIMENTAL DATA.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:UNKNOWN	  IARC:UNKNOWN	  OSHA:YES
Health Hazards Acute and Chronic:SKIN: POS FROST BITE/MILD
    IRRIT/SENSITIZATION. EYES: IRRIT/TEARING/BLURRY VISION. INHAL: POS
    NAUSEA/HEADACHE/WEAKNESS. TEMPORARY NS DEPRESSION W/DIZZINESS,
    HEADACHE, CONFUSION, INCOORDINATION, LOSS CO NSCIOUSNESS. HIGH
    EXPOS, >20% MAY LEAD TEMPORARY LUNG IRRIT
    W/COUGH/DISCOMFORT/DIFFICULT BREATHING/SHORTNESS BREATH;*
Explanation of Carcinogenicity:CONTAINS 2-A		      [53-96-3]
    WHICH IS LISTED BY NTP AND IARC AND REGULATED BY OSHA AS A
    CARCINOGEN.
Effects of Overexposure:NK     *TEMP ALTERATION OF HEART ELECTRICAL
    ACTIVITY W/IRREG PULSE/PALPITATIONS/INADEQUATE CIRCULATION/ABNORMAL
    KIDNEY FUNCTION/FATALITY FROM GROSS OVEREXPOSURE.
Medical Cond Aggravated by Exposure:INDIVIDUALS W/PREEXISTING DISEASES
    OF CNS, CARDIOVASCULAR SYSTEM, LUNGS OR KIDNEYS MAY HAVE INCREASED
    SUSCEPTIBILITY TO TOXICITY OF EXCESSIVE EXPOSURES.

=======================  First Aid Measures  =======================

First Aid:INHAL: GET FRESH AIR IMMED. KEEP CALM. IF NOT BREATHING GIVE
    ARTIF RESP. IF BREATHING DIFFICULT, GIVE OXYGEN. CALL DR. SKIN:
    FLUSH W/WATER 15 MIN. IF FROST BITE, WARM AFFECTED AREAS. GET MED
    AID IF IR RIT PRESENT. EYES: FLUSH IMMED W/LOTS H2O 15 MIN. CALL
    DR. NOTE TO DR.: BECAUSE POS CARDIAC RHYTHM DISTURBANCE,
    CATECHOLANINE DRUGS (EPINEPHRINE) SHOULD BE USED W/SPECIAL CAUTION
    IN EMER LIFE SUPPORT.

=====================  Fire Fighting Measures  =====================

Flash Point:NONE
Extinguishing Media:AS APPROPRIATE FOR COMBUSTIBLES IN AREA.
Fire Fighting Procedures:SCBA REQUIRED IF CYLINDERS RUPTURE/RELEASE
    UNDER FIRE CONDITIONS.
Unusual Fire/Explosion Hazard:USE WATER SPRAY/FOG TO COOL CONTAINERS.
    CYLINDERS ARE EQUIPPED W/TEMP & PRESSURE RELIEF DEVICES BUT MAY
    STILL RUPTURE UNDER FIRE CONDITIONS. DECOMP POSSIBLE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:REVIEW FIRE EXPLN HAZ/SAFETY PRECAUTIONS
    BEFORE CLEAN UP. USE APPROPRIATE PERSONAL PROTECTIVE EQUIP.
    VENTILATE AREA, ESPEC LOW PLACES WHERE VAPORS MIGHT COLLECT. USE
    SCBA FOR LARGE SPILLS. REMOVE OPEN	FLAMES.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE CONTAINERS IN COOL, CLEAN DRY
    AREA. DO NOT ALLOW TEMP TO RISE ABOVE 125F.
Other Precautions:AVOID BREATHING VAPORS. AVOID LIQUID CONTACT
    W/SKIN/EYES. USE SUFFICIENT VENTILATION TO KEEP EMPLOYEE EXPOSURE
    BELOW RECOMMENDED LIMITS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NOT REQUIRED UNDER NORMAL MFG CONDITIONS. SCBA
    REQUIRED IF SPILL OCCURS.
Ventilation:NORMAL FOR STANDARD MFG ADEQUATE. LOCAL EXHAUST WHEN LG
    AMTS RELEASED. MECHANCL VENT SHOULD BE USED IN LOW PLACES.
Protective Gloves:RUBBER,PLASTIC
Eye Protection:CHEMICAL SPLASH GOGGLES
Other Protective Equipment:USE GLOVES & FACE SHIELD WHEN HANDLING
    LIQUID
Supplemental Safety and Health
INHALATION 4-HR ALC = 383,000 PPM RATS. ORAL ALD RATS = >1500 MG/KG.

==================  Physical/Chemical Properties  ==================

HCC:G3
Boiling Pt:B.P. Text:-28F (-33C)
Vapor Pres:232 PSIA
Vapor Density:3.7
Evaporation Rate & Reference:<1 (CCL4 - 1.0)
Appearance and Odor:COLORLESS LIQUID, SLIGHT ETHERAL ODOR.
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
ALKALI/ALKALINE EARTHMETALS. AVOID POWDERED AL, ZN, BE,ETC.
Stability Condition to Avoid:OPEN FLAMES, HIGH TEMPERATURES.
Hazardous Decomposition Products:HYDROCHLORIC/HYDROFLUORIC ACIDS.
    POSSIBLY CARBONYL HALIDES.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE IN COMPLIANCE W/APPLICABLE LAWS. RECLAIM
    BY DISTILLATION OR REMOVE TO PERMITTED WASTE DISPOSAL FACILITY.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.