DYNALOY INC -- DYNASOLVE 165 -- 6850-00N057506
=====================  Product Identification  =====================

Product ID:DYNASOLVE 165
MSDS Date:11/01/1989
FSC:6850
NIIN:00N057506
=== Responsible Party ===
Company Name:DYNALOY INC
Address:7 GREAT MEADOW LANE
City:HANOVER
State:NJ
ZIP:07936
Country:US
Info Phone Num:201-887-9270
Emergency Phone Num:201-887-9270
Preparer's Name:JAY W. PARTON
CAGE:27905
=== Contractor Identification ===
Company Name:DYNALOY INC
Address:7 GREAT MEADOW LN
City:EAST HANOVER
State:NJ
ZIP:07936-1703
Country:US
Phone:201-887-9270/201-887-3678 FAX
CAGE:27905
Company Name:DYNALOY, INC.
Address:1910 SOUTH STATE AVE.
Box:City:INDIANAPOLIS
State:IN
ZIP:46203
Country:US
Phone:317-788-9925;703-527-3887
CAGE:27908

=============  Composition/Information on Ingredients  =============

Ingred Name:METHANE, DICHLORO-; (METHYLENE CHLORIDE) (DICHLOROMETHANE) 
    (SARA 313) (CERCLA)
CAS:75-09-2
RTECS #:PA8050000
Fraction by Wt: 80-90%
OSHA PEL:500 PPM
ACGIH TLV:50 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:ACETIC ACID; (ETHANOIC ACID)  (CERCLA)
CAS:64-19-7
RTECS #:AF1225000
Fraction by Wt: 7-10%
OSHA PEL:10 PPM
ACGIH TLV:10 PPM;15 STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:FORMIC ACID; (METHANOIC ACID)  (SARA 313) (CERCLA)
CAS:64-18-6
RTECS #:LQ4900000
Fraction by Wt: 5-15%
OSHA PEL:5 PPM
ACGIH TLV:5 PPM;10 STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:BENZENESULFONIC ACID, DODECYL-; (BENZENESULFONIC ACID) 
    (CERCLA)
CAS:27176-87-0
RTECS #:DB6600000
Fraction by Wt: 0.5-5%
OSHA PEL:N/K 
ACGIH TLV:N/K 
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:OTHER PREC:APPRVD RESP PROT MAY BE REQD TO REDUCE POTNTL
    FOR OVEREXP TO VAPS. DO NOT PUMP AT HIGH PRESS. USE (ING 6)
RTECS #:9999999ZZ

Ingred Name:ING 5:TEFLON PACKINGS. USE OF AIR FOR UNLOADING PROD OUT OF
    VESSELS/TRANSPORT CNTNRS IS NOT REC. MATLS OF (ING 7)
RTECS #:9999999ZZ

Ingred Name:ING 6:CONSTRUCTION FOR TANKS ARE POLYETHYLENE,
    POLYPROPYLENE & GLASS LINED STEEL. NO SMOKING IN AREA OF USE. DO
    (ING 8)
RTECS #:9999999ZZ

Ingred Name:ING 7:NOT USE IN THE GENERAL VICINITY OF ARC WELDING, OPEN
    FLAMES OR HOT SURFACES. HEAT &/OR UV RADIATION MAY (ING 9)
RTECS #:9999999ZZ

Ingred Name:ING 8:CAUSE THE FORMATION OF HCL &/OR PHOSGENE .
RTECS #:9999999ZZ

Ingred Name:EYE PROT:& FULL LENGTH FACESHIELD .
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:NO
Health Hazards Acute and Chronic:ACUTE:BURNS TO SKIN, EYES/MOUTH, RESP
    TRACT IRRIT, DIZZ, HDCH, VERTIGO, NAUS, DROW, NARCOS, UNCON,
    CARDIAC ARRYTHMIA, CARBOXYHEMOGLOBINEMIA, LUNG DMG, LOSS OF WT,
    PARALYSIS, ABDOM PAIN & DISTRESS, BLI NDNESS. CHRONIC:SKIN IRRIT,
    DERM, DIGEST DISTURBS, CNS EFTS, KIDNEY/LIVER DMG. ALTHOUGH RSLTS
    OF AMES (EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE:IARC MONOGRAPHS SUPP,
    VOL 7, PG 194, 1987:GRP 2B. NTP 7TH ANNUAL RPT ON CARCINS,
    1994:ANTIC (SUPDAT)
Effects of Overexposure:HLTH HAZ:BACTERIAL TESTS HAVE GENERALLY BEEN
    POSITIVE, OVERALL DATA SUGGEST THAT GENOTOX POTNTL DOES NOT APPEAR
    TO BE SIGNIFICANT FACTOR IN TOX OF METHYLENE CHLORIDE. CHLOROCARBON
    MATLS HAVE PRDCD SEN SIT OF MYOCARDIUM TO EPINEPHRINE IN LABANIMALS
    & COULD HAVE SIMILAR EFT IN HUMANS. ADRENOMIMETICS (E.G., (SUPP
    DATA)
Medical Cond Aggravated by Exposure:SKIN ALLERGIES, RESPIRATORY
    CONDITIONS.

=======================  First Aid Measures  =======================

First Aid:INHAL:REMOVE TO FRESH AIR. IF BREATHING HAS STOPPED, GIVE
    ARTF RESP, ADMINISTER OXYGEN. CALL MD. EYES:FLUSH W/WATER,
    INCLUDING UNDER EYELIDS, FOR AT LEAST 15 MINUTES. CALL MD.
    SKIN:REMOVE CONTAMINATED  CLOTHING. FLUSH W/WATER FOR 15 MINUTES,
    THEN WASH W/SOAP & WATER. CALL MD. INGEST:DO NOT INDUCE VOMITING.
    IF CONSCIOUS, DILUTE W/WATER, MILK OR MILK OF MAGENSIA. CALL MD.

=====================  Fire Fighting Measures  =====================

Flash Point:NONE
Lower Limits:14%
Upper Limits:22%
Extinguishing Media:WATER FOG, CO*2, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA &
    FULL PROTECTIVE EQUIPMENT . NO SKIN SURFACE SHOULD BE EXPOSED. USE
    WATER SPRAY TO KEEP CONTAINERS COOL.
Unusual Fire/Explosion Hazard:THERMAL DECOMP PRODS MAY INCL HCL &
    PHOSGENE. FORMS FLAMM VAP-AIR MIXTS. LOWER TEMPS INCR DFCLTY OF
    GETTING IT TO IGNITE. CONC VAPS CAN BE IGNITED(SUPDAT)

==================  Accidental Release Measures  ==================

Spill Release Procedures:EVACUATE AREA, VENTILATE, AVOID BREATHING
    VAPORS, CONTAIN SPILL. CLEAN UP AREA (WEAR PROTECTIVE CLOTHING)
    USING A NON-COMBUSTIBLE ABSORBENT MATERIAL. PLACE IN A CLOSED
    CONTAINER. FLUSH AREA W/WATER. D O NOT ALLOW TO GET INTO WATERWAYS.
Neutralizing Agent:USE OF LIME OR SODA ASH MAY HELP TO NEUTRALIZE THIS
    PRODUCT.

======================	Handling and Storage  ======================

Handling and Storage Precautions:AVOID CONT W/SKIN & AVOID BRTHG VAPS.
    STORE IN COOL, DRY, VENTILATED AREA. VAPS ARE HVR/AIR & WILL
    COLLECT IN LOW AREAS. KEEP CNTNR SEALED. CORR MATL.
Other Precautions:NO SMOKING IN PRESENCE OF VAPS. MANUAL OPERATIONS
    INVOLVING POTNTL FOR SKIN CONT, SUCH AS CLEANING OPERATIONS
    INVOLVING LG SURFS, SHOULD BE APPROACHED W/SPECIAL CAUT, DUE TO
    VOLATILITY OF METHYLENE CH LORIDE. INCR VENT OR NIOSH/MSHA (ING 5)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:AN APPROPRIATE NIOSH/MSHA APPROVED FULL-FACE
    RESPIRATOR FOR ORGANIC VAPOR &/OR MIST SHOULD BE WORN IF NEEDED.
    FOR HIGH CONCENTRATIONS, USE A NIOSH/MSHA APPROVED POSITIVE
    PRESSURE SCBA.
Ventilation:LOCAL EXHAUST: WELL-VENTILATED AREA. MECHANICAL (GENERAL):
    EXHAUST HOOD. SPECIAL: EXPLOSION PROOF.
Protective Gloves:CHEM RESIST GLOVES (BUTYL RUBBER).
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(ING 10)
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
    ANSI DESIGN CRITERIA . IMPERVIOUS APRON.
Work Hygienic Practices:CONTACT LENSES SHOULD NOT BE WORN. LAUNDER
    CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
EXPLO HAZ:BY HIGH INTENSITY HEAT SOURCE. MATLS TO AVOID:SODIUM,
    POTASSIUM & MAGNESIUM. EXPLAN OF CARCIN:TO BE CARCIN. ANIMAL:LUNG,
    LIVER, SALIVARY, MAMMARY GLAND (TUMORS). EFTS OF
    OVEREXP:EPINEPHRINE)  MAY BE CONTRAINDICATED EXCEPT FOR
    LIFE-SUSTAINING USES IN HUMANS ACUTELY/CHRONICALLY EXPOS TO
    CHLOROCARBONS .

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:104F,40C
Vapor Pres:355 @ 20C
Vapor Density:2.93
Spec Gravity:1.29 (H*2O=1)
Evaporation Rate & Reference:0.7 (ETHER=1)
Solubility in Water:2 GM/100 GM @ 75C
Appearance and Odor:CLEAR LIQUID; STRONG ACETIC ACID - CHLORINATED
    SOLVENT ODOR.
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
ACIDS, ALKALIS, OXIDIZERS, AMINES, CALCIUM HYPOCHLORIDE, HYDROGEN
    PEROXIDE, FURFURYL ALCOHOL, ALUMINUM, POSSIBLY(SUPDAT)
Stability Condition to Avoid:OPEN FLAME, HOT SURFACES, ELECTRICAL ARCS.
Hazardous Decomposition Products:HYDROGEN CHLORIDE, CO, CO*2, PHOSGENE,
    FORMIC ACID VAPORS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:INCINERATE I/A/W FEDERAL, STATE & LOCAL
    REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.