CRC INDUSTRIES,INC. -- BRAKLEEN AEROSOL 05089, 05089P, 05089T -- 6850-01-158-3928
===================== Product Identification ===================== Product ID:BRAKLEEN AEROSOL 05089, 05089P, 05089T MSDS Date:01/26/1999 FSC:6850 NIIN:01-158-3928 Status Code:A === Responsible Party === Company Name:CRC INDUSTRIES,INC. Address:885 LOUIS DR. City:WARMINSTER State:PA ZIP:18974 Country:US Info Phone Num:215-674-4300 Emergency Phone Num:(800)424-9300 Preparer's Name:ADAM SELISKER Chemtrec Ind/Phone:(800)424-9300 CAGE:023V4 === Contractor Identification === Company Name:ABSCOA INDUSTRIES INC Address:2000 ROBOTICS PL Box:185369 City:FORT WORTH State:TX ZIP:76118-7129 Country:US Phone:817-284-4449 Contract Num:SP0450-99-M-C808 CAGE:2N335 Company Name:CRC INDUSTRIES, INC. Address:885 LOUIS DRIVE Box:City:WARMINSTER State:PA ZIP:18974-2869 Country:US Phone:215-674-4300/ 800-521-3168 CAGE:023V4 Company Name:CRC INDUSTRIES, INC. Address:885 LOUIS DRIVE Box:City:WARMINSTER State:PA ZIP:18974-2820 Country:US Phone:215-674-4300/800-424-9300 CAGE:10136 ============= Composition/Information on Ingredients ============= Ingred Name:TETRACHLOROETHYLENE CAS:127-18-4 RTECS #:KX3850000 > Wt:90. OSHA PEL:see Table Z-2 ACGIH TLV:170 MG/M3;25 PPM ACGIH STEL:685 MG/M3;100 PPM EPA Rpt Qty:100 LBS DOT Rpt Qty:100 LBS Ingred Name:CARBON DIOXIDE CAS:124-38-9 RTECS #:FF6400000 < Wt:10. OSHA PEL:9000 MG/M3;5000 PPM ACGIH TLV:9000 MG/M3;5000 PPM ACGIH STEL:54000 MG/M3 ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES Health Hazards Acute and Chronic:EYES & SKIN: IRRITATION. INHALATION: CAUSES CENTRAL NERVOUS SYSTEM EFFECTS, HEADACHES, DIZZINESS, DRUNKENESS, IRRITATION TO UPPER TRACT, UNCONSCIOUSNESS & IRREGULAR HEARTBEATS. CHRONIC: REPEATED OVERE XPOSURE HAVE CAUSED LIVER EFFECTS. Explanation of Carcinogenicity:TETRACHLOROETHYLENE IS LISTED AS A CARCINOGEN. Effects of Overexposure:EYES & SKIN-IRRITATION. INHALATION: HEADACHES, DIZZINESS, DRUNKENESS, IRRITATION TO UPPER RESPIRATORY TRACT, UNCONSCIOUSNESS, IRREGULAR HEARTBEATS. Medical Cond Aggravated by Exposure:RISK TO YOUR HEALTH DEPENDS ON THE LEVEL AND DURATION OF EXPOSURE. ======================= First Aid Measures ======================= First Aid:INHALATION-REMOVE TO FRESH AIR. APPLY ARTIFICIAL RESPIRATION IF NECESSARY. EYES-FLUSH WITH LARGE AMOUNTS OF WATER. FOR 15 MINUTES. SKIN-REMOVE CONTAMINATED CLOTHES. WASH EXPOSED AREAS WITH SOAP & WATE R. INGESTED-DO NOT INDUCE VOMITING! CALLA PHYSICIAN. ===================== Fire Fighting Measures ===================== Flash Point Method:TCC Flash Point:NONE Lower Limits:N/D Upper Limits:N/D Extinguishing Media:WATER FOG. Fire Fighting Procedures:REMOVE CONTAINERS FROM FIRE AREA IF POSSIBLE. USE SELF-CONTAINED BREATHING APPARATUS FOR FIRE FIGHTING. AEROSOL CANS MAY EXPLODE IF HEATED ABOVE 120F. HYDROGEN CHLORIDE AND SOME PHOSGENE FORMED DURING COMBUSTION. ================== Accidental Release Measures ================== Spill Release Procedures:USUALLY NOT A PROBLEM WITH AEROSOLS. AREA SHOULD BE VENTILATED. ABSORBENT SHOULD BE USED TO PICK UP EXCESS MATERIAL. ALL USED AND UNUSED PRODUCT SHOULD BE DISPOSED OF IN ACCORDANCE WITH FEDERAL, STST E, AND LOCAL REGULATIONS. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:STORE IN A COOL, DRY AREA.AEROSOL CANS MUST BE MAINTAINED BELOW 120F TO PREVENT CANS FROM EXPLODING. Other Precautions:AVOID CONTACT WITH SKIN. AVOID BREATHING OF VAPOR. VAPORS ARE HEAVIER THAN AIR AND WILL COLLECT IN LOW AREAS, DO NOT ENTER UNLESS SPECIAL BREATHING APPARATUS IS USED AND AN OBERVER IS PRESENT FOR ASSI STANCE. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:USE NIOSH/MSHA COMPLIANT RESPIRATORS OR SELF-CONTAINED BREATHING APPARATUS ABOVE EXPOSURE LIMITS. FOLLOW OSHA REGUALTIONS 29CFR 1910.134. POSITIVE PRESSURE SELF-CONTAINED BREATHING APPARATUS IF ACCUMU LATION OF VAPORS IS SUSPECTED. Ventilation:ADEQUATE TO PREVENT THE ACCUMULATION OF VAPORS.USE MECHANICAL MEANS TO MAINTAIN LEVELS BELOW EXPOSURE LIMITS. Protective Gloves:CHEMICALLY PROTECTIVE GLOVES. Eye Protection:SAFETY GLASSES. Other Protective Equipment:SPLASH APRON AND BOOTS IFSPLASHING OCCURS. Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER. Supplemental Safety and Health NONE SPECIFIED BY MANUFACTURER. ================== Physical/Chemical Properties ================== HCC:V2 Boiling Pt:=121.1C, 250.F Melt/Freeze Pt:M.P/F.P Text:ND Vapor Pres:13 MMHG Vapor Density:>AIR Spec Gravity:1.619 Evaporation Rate & Reference:RAPID, NO REFERENCE Solubility in Water:SLIGHT Appearance and Odor:COLORLESS LIQUID, IRRITATING ODOR AT HIGH CONCENTRATIONS. ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES AVOID STORAGE IN ALUMINUM CONTAINERS OR CONTACT WITH ALUMINUM AND/OR ZINC POWDERS. Stability Condition to Avoid:STRONG OXIDIZERS Hazardous Decomposition Products:NONE =================== Toxicological Information =================== Toxicological Information:NONE SPECIFIED BY MANUFACTURER. ===================== Ecological Information ===================== Ecological:NONE SPECIFIED BY MANUFACTURER. ==================== Disposal Considerations ==================== Waste Disposal Methods:ALL USED AND UNUSED PRODUCT SHOULD BE DISPOSED OF IN CONFORMANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS.DO NOT DUMP INTO SEWERS, ON THE GROUND OR INTO ANY BODY OF WATER. =================== MSDS Transport Information =================== Transport Information:NONE SPECIFIED BY MANUFACTURER. ===================== Regulatory Information ===================== SARA Title III Information:THIS PRODUCT CONTAINS THE FOLLOWING CHEMICALS THAT ARE SUBJECT TO RELEASE REPORTING UNDER SECTION 313 OF SARA TITLE III: TETRACHLOROETHYLENE, CAS# 127-18-4, >90. Federal Regulatory Information:NONE SPECIFIED BY MANUFACTURER. State Regulatory Information:NONE SPECIFIED BY MANUFACTURER. ======================= Other Information ======================= Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.