CRC INDUSTRIES,INC. -- BRAKLEEN AEROSOL 05089, 05089P, 05089T -- 6850-01-158-3928
===================== Product Identification =====================
Product ID:BRAKLEEN AEROSOL 05089, 05089P, 05089T
MSDS Date:01/26/1999
FSC:6850
NIIN:01-158-3928
Status Code:A
=== Responsible Party ===
Company Name:CRC INDUSTRIES,INC.
Address:885 LOUIS DR.
City:WARMINSTER
State:PA
ZIP:18974
Country:US
Info Phone Num:215-674-4300
Emergency Phone Num:(800)424-9300
Preparer's Name:ADAM SELISKER
Chemtrec Ind/Phone:(800)424-9300
CAGE:023V4
=== Contractor Identification ===
Company Name:ABSCOA INDUSTRIES INC
Address:2000 ROBOTICS PL
Box:185369
City:FORT WORTH
State:TX
ZIP:76118-7129
Country:US
Phone:817-284-4449
Contract Num:SP0450-99-M-C808
CAGE:2N335
Company Name:CRC INDUSTRIES, INC.
Address:885 LOUIS DRIVE
Box:City:WARMINSTER
State:PA
ZIP:18974-2869
Country:US
Phone:215-674-4300/ 800-521-3168
CAGE:023V4
Company Name:CRC INDUSTRIES, INC.
Address:885 LOUIS DRIVE
Box:City:WARMINSTER
State:PA
ZIP:18974-2820
Country:US
Phone:215-674-4300/800-424-9300
CAGE:10136
============= Composition/Information on Ingredients =============
Ingred Name:TETRACHLOROETHYLENE
CAS:127-18-4
RTECS #:KX3850000
> Wt:90.
OSHA PEL:see Table Z-2
ACGIH TLV:170 MG/M3;25 PPM
ACGIH STEL:685 MG/M3;100 PPM
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS
Ingred Name:CARBON DIOXIDE
CAS:124-38-9
RTECS #:FF6400000
< Wt:10.
OSHA PEL:9000 MG/M3;5000 PPM
ACGIH TLV:9000 MG/M3;5000 PPM
ACGIH STEL:54000 MG/M3
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:EYES & SKIN: IRRITATION. INHALATION:
CAUSES CENTRAL NERVOUS SYSTEM EFFECTS, HEADACHES, DIZZINESS,
DRUNKENESS, IRRITATION TO UPPER TRACT, UNCONSCIOUSNESS & IRREGULAR
HEARTBEATS. CHRONIC: REPEATED OVERE XPOSURE HAVE CAUSED LIVER
EFFECTS.
Explanation of Carcinogenicity:TETRACHLOROETHYLENE IS LISTED AS A
CARCINOGEN.
Effects of Overexposure:EYES & SKIN-IRRITATION. INHALATION: HEADACHES,
DIZZINESS, DRUNKENESS, IRRITATION TO UPPER RESPIRATORY TRACT,
UNCONSCIOUSNESS, IRREGULAR HEARTBEATS.
Medical Cond Aggravated by Exposure:RISK TO YOUR HEALTH DEPENDS ON THE
LEVEL AND DURATION OF EXPOSURE.
======================= First Aid Measures =======================
First Aid:INHALATION-REMOVE TO FRESH AIR. APPLY ARTIFICIAL RESPIRATION
IF NECESSARY. EYES-FLUSH WITH LARGE AMOUNTS OF WATER. FOR 15
MINUTES. SKIN-REMOVE CONTAMINATED CLOTHES. WASH EXPOSED AREAS WITH
SOAP & WATE R. INGESTED-DO NOT INDUCE VOMITING! CALLA PHYSICIAN.
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:NONE
Lower Limits:N/D
Upper Limits:N/D
Extinguishing Media:WATER FOG.
Fire Fighting Procedures:REMOVE CONTAINERS FROM FIRE AREA IF POSSIBLE.
USE SELF-CONTAINED BREATHING APPARATUS FOR FIRE FIGHTING. AEROSOL
CANS MAY EXPLODE IF HEATED ABOVE 120F. HYDROGEN CHLORIDE AND SOME
PHOSGENE FORMED DURING COMBUSTION.
================== Accidental Release Measures ==================
Spill Release Procedures:USUALLY NOT A PROBLEM WITH AEROSOLS. AREA
SHOULD BE VENTILATED. ABSORBENT SHOULD BE USED TO PICK UP EXCESS
MATERIAL. ALL USED AND UNUSED PRODUCT SHOULD BE DISPOSED OF IN
ACCORDANCE WITH FEDERAL, STST E, AND LOCAL REGULATIONS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN A COOL, DRY AREA.AEROSOL CANS
MUST BE MAINTAINED BELOW 120F TO PREVENT CANS FROM EXPLODING.
Other Precautions:AVOID CONTACT WITH SKIN. AVOID BREATHING OF VAPOR.
VAPORS ARE HEAVIER THAN AIR AND WILL COLLECT IN LOW AREAS, DO NOT
ENTER UNLESS SPECIAL BREATHING APPARATUS IS USED AND AN OBERVER IS
PRESENT FOR ASSI STANCE.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE NIOSH/MSHA COMPLIANT RESPIRATORS OR
SELF-CONTAINED BREATHING APPARATUS ABOVE EXPOSURE LIMITS. FOLLOW
OSHA REGUALTIONS 29CFR 1910.134. POSITIVE PRESSURE SELF-CONTAINED
BREATHING APPARATUS IF ACCUMU LATION OF VAPORS IS SUSPECTED.
Ventilation:ADEQUATE TO PREVENT THE ACCUMULATION OF VAPORS.USE
MECHANICAL MEANS TO MAINTAIN LEVELS BELOW EXPOSURE LIMITS.
Protective Gloves:CHEMICALLY PROTECTIVE GLOVES.
Eye Protection:SAFETY GLASSES.
Other Protective Equipment:SPLASH APRON AND BOOTS IFSPLASHING OCCURS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
================== Physical/Chemical Properties ==================
HCC:V2
Boiling Pt:=121.1C, 250.F
Melt/Freeze Pt:M.P/F.P Text:ND
Vapor Pres:13 MMHG
Vapor Density:>AIR
Spec Gravity:1.619
Evaporation Rate & Reference:RAPID, NO REFERENCE
Solubility in Water:SLIGHT
Appearance and Odor:COLORLESS LIQUID, IRRITATING ODOR AT HIGH
CONCENTRATIONS.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
AVOID STORAGE IN ALUMINUM CONTAINERS OR CONTACT WITH ALUMINUM AND/OR
ZINC POWDERS.
Stability Condition to Avoid:STRONG OXIDIZERS
Hazardous Decomposition Products:NONE
=================== Toxicological Information ===================
Toxicological Information:NONE SPECIFIED BY MANUFACTURER.
===================== Ecological Information =====================
Ecological:NONE SPECIFIED BY MANUFACTURER.
==================== Disposal Considerations ====================
Waste Disposal Methods:ALL USED AND UNUSED PRODUCT SHOULD BE DISPOSED
OF IN CONFORMANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS.DO NOT
DUMP INTO SEWERS, ON THE GROUND OR INTO ANY BODY OF WATER.
=================== MSDS Transport Information ===================
Transport Information:NONE SPECIFIED BY MANUFACTURER.
===================== Regulatory Information =====================
SARA Title III Information:THIS PRODUCT CONTAINS THE FOLLOWING
CHEMICALS THAT ARE SUBJECT TO RELEASE REPORTING UNDER SECTION 313
OF SARA TITLE III: TETRACHLOROETHYLENE, CAS# 127-18-4, >90.
Federal Regulatory Information:NONE SPECIFIED BY MANUFACTURER.
State Regulatory Information:NONE SPECIFIED BY MANUFACTURER.
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.