MARTIN-SENOUR AUTOMOTIVE SALES -- ACRYLIC ENAMEL REDUCER HOT WEATHER, 8833 -- 8010-00N022883
===================== Product Identification =====================
Product ID:ACRYLIC ENAMEL REDUCER HOT WEATHER, 8833
MSDS Date:02/08/1988
FSC:8010
NIIN:00N022883
=== Responsible Party ===
Company Name:MARTIN-SENOUR AUTOMOTIVE SALES
Address:5422 DANSHER RD
City:COUNTRYSIDE
State:IL
ZIP:60525
Country:US
Info Phone Num:216-566-2902
Emergency Phone Num:216-566-2917
CAGE:MART3
=== Contractor Identification ===
Company Name:MARTIN-SENOUR AUTOMOTIVE SALES
Address:5422 DANSHER RD
City:COUNTRYSIDE
State:IL
ZIP:60525
Country:US
Phone:216-566-2902
CAGE:MART3
Company Name:MARTIN-SENOUR CO THE DIV SHERWIN-WILLIAMS CO
Address:2500 S SENOUR AVE
Box:City:CHICAGO
State:IL
ZIP:60608-5724
Country:US
CAGE:16772
============= Composition/Information on Ingredients =============
Ingred Name:NAPHTHA, LIGHT AROMATIC. VP:3.8
CAS:64742-95-6
Fraction by Wt: <5%
OSHA PEL:100 PPM
ACGIH TLV:100 PPM
Ingred Name:METHANOL;(METHYL ALCOHOL.) VP:92.0
CAS:67-56-1
RTECS #:PC1400000
Fraction by Wt: <5%
OSHA PEL:S,200PPM/250STEL
ACGIH TLV:S,200PPM/250STEL; 93
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ingred Name:ACETONE. VP:180.0
CAS:67-64-1
RTECS #:AL3150000
Fraction by Wt: <5%
OSHA PEL:1000PPM
ACGIH TLV:750PPM/1000STEL;9293
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ingred Name:ETHANOL, 2-BUTOXY-,ACETATE;(ETHYLENE GLYCOL MONOBUTYL ETHER
ACETATE.) VP:1.0
CAS:112-07-2
RTECS #:KJ8925000
Fraction by Wt: 15%
ACGIH TLV:50 PPM (MFR)
Ingred Name:OTHER PREC:& APPLIANCES & ANY OTHER SOURCES OF IGNIT.
CONSULT NFPA CODE. USE APPRVD BONDING & GROUNDING (ING 9)
RTECS #:9999999ZZ
Ingred Name:ING 8:PROCEDURES. TRANSFER ONLY TO APPRVD CONTRS W/COMPLETE
& APPROP LBLG. DO NOT TAKE INTERNALLY. KEEP OUT OF (ING 10)
RTECS #:9999999ZZ
Ingred Name:ING 9:THE REACH OF CHILDREN. INTENTIONAL MISUSE BY
DELIBERATELY CONCENTRATING & INHALING THE CONTENTS CAN BE (ING 11)
RTECS #:9999999ZZ
Ingred Name:ING 10:HARMFUL OR FATAL.
RTECS #:9999999ZZ
Ingred Name:RESP PROT:APPRVD DUST MASK OR PARTICULATE RESPIRATOR.
RTECS #:9999999ZZ
Ingred Name:VENT:EXPOSURE LIMITS. REFER TO OSHA STANDARDS 1910.94,
1910.107, 1910.108.
RTECS #:9999999ZZ
Ingred Name:TOLUENE (SARA III)
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: 25%
OSHA PEL:200 PPM/150 STEL
ACGIH TLV:50 PPM; 9293
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:BENZENE, ETHYL-;(ETHYL BENZENE.) VP:7.1
CAS:100-41-4
RTECS #:DA0700000
Fraction by Wt: <5%
OSHA PEL:100 PPM;125 PPM STEL
ACGIH TLV:100 PPM;125 PPM STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:XYLENE. VP:5.9
CAS:1330-20-7
RTECS #:ZE2100000
Fraction by Wt: 45%
OSHA PEL:100 PPM;150 PPM STEL
ACGIH TLV:100 PPM;150 PPM STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:ALCOHOLS & ACETATES CAN BE
ABSORBED THRU THE SKIN. IRRIT OF EYES, SKIN & RESP SYS. MAY CAUSE
NERV SYS DEPRESS. EXTREME OVEREXPOS MAY RSLT IN UNCON & POSS DEATH.
CHRONIC:PRLNGD OVEREXPOS TO SOLV INGREDS MAY CAUSE ADVERSE EFTS TO
THE LIVER, URINARY, BLOOD FORMING, CARDIO-VASCULAR & REPROD SYS.
(SEE EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:RPTS HAVE ASSOC RPTD/PRLNGD OVEREXPOS
TO SOLV W/PERM BRAIN & NERV SYS DAM. HDCH, DIZZ, NAUS & LOSS OF
COORDINATION ARE INDICATIONS OF EXCESSIVE EXPOS TO VAPS/SPRAY MIST.
REDNESS, ITCHING OR B URNING SENSATION MAY INDICATE EYE OR
EXCESSIVE SKIN EXPOSURE.
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.
======================= First Aid Measures =======================
First Aid:INHAL:IF AFFECTED, REMOVE FROM EXPOSURE. RESTORE BREATHING.
KEEP WARM & QUIET. SKIN:WASH AFFECTED AREA THOROUGHLY W/SOAP &
WATER. REMOVE CONTAMINATED CLOTHING & LAUNDER BEFORE REUSE.
EYE:FLUSH W/LARGE AMOUNTS OF WATER FOR AT LEAST 15 MINS.GET MD.
INGEST:NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. DO
NOT INDUCE VOMITING. GIVE SEVERAL GLASSES OF WATER. SEEK MD.
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:10F,-12C
Lower Limits:0.5
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL OR FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. WATER SPRAY MAY BE INEFT. IF WATER IS USED, FOG NOZZ ARE
PREFERABLE. WATER MAY BE USED TO (SEE SUPP DATA)
Unusual Fire/Explosion Hazard:KEEP CONTRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPARKS & OPEN FLAME. CLSD CONTRS MAY EXPLODE WHEN
EXPOSED TO EXTREME HEAT. APPLICATN TO (SEE SUPP DATA)
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE &
REMOVE W/INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:CONTENTS ARE EXTREMELY FLAM. KEEP AWAY
FROM HEAT, SPARKS & OPEN FLAME. VAPS WILL ACCUM READILY & MAY
IGNITE EXPLOSIVELY. USE ONLY W/ADEQ VENT.
Other Precautions:KEEP CONTR CLSD WHEN NOT IN USE. AVOID BRTHG
VAP/SPRAY MIST. AVOID CONT W/SKIN & EYES. DURING USE & UNTIL ALL
VAPS ARE GONE:KEEP AREA VENTD. DO NOT SMOKE. EXTING ALL FLAMES,
PILOT LIGHTS & HEATER. TUR N OFF STOVE, ELEC TOOLS (SEE INGRED 8)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IF PERSONAL EXPOS CANNOT BE CONTROLLED BELOW
APPLIC LIMITS BY VENT, WEAR A NIOSH/MSHA APPRVD PROPERLY FITTED ORG
VAP/PARTICULATE RESP FOR PROT AGAINST MATLS IN INGREDS. WHEN
SANDING/ABRADING THE DRIED FILM, WEAR A NIOSH/MSHA (SEE INGRED 12)
Ventilation:LOC EXHST PREFERABLE. GEN EXHST ACCEPTABLE IF THE EXPOS TO
MATLS IN INGREDS IS MAINTAINED BELOW APPLIC (SEE INGRED 13)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
FIRE FIGHT PROC:COOL CLSD CONTRS TO PVNT PRESS BUILD-UP & POSS
AUTOIGNIT OR EXPLOS WHEN EXPOSED TO EXTREME HEAT. EXPLO HAZ:HOT
SURF REQUIRES SPEC PRECS. DURING EMER CNDTNS OVEREXPOS TO DECOMP
PRODS MA Y CAUSE A HLTH HAZ. SYMPS MAY NOT BE IMMED APPARENT.
OBTAIN MED ATTN. WASTE DISP METH:REGARDING POLLUTION.
================== Physical/Chemical Properties ==================
HCC:F3
Boiling Pt:B.P. Text:132F,56C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY FIRE: CARBON DIOXIDE & CARBON
MONOXIDE.
==================== Disposal Considerations ====================
Waste Disposal Methods:WASTE FROM THIS PROD MAY BE HAZ AS DEFINED UNDER
THE RCRA 40CFR261. WASTE MUST BE TESTED FOR IGNITABILITY TO DETERM
THE APPLIC EPA HAZ WASTE NO. INCIN IN APPRVD FACILITY. DO NOT INCIN
CLSD CONTR. DISP OF I/A/W FED, STATE & LOCAL REGS (SEE SUPP DATA)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.