HACH CO. -- 1072 ALKALINE IODIDE-AZIDE REAGENT -- 6810-00D001386
=====================  Product Identification  =====================

Product ID:1072 ALKALINE IODIDE-AZIDE REAGENT
MSDS Date:07/15/1986
FSC:6810
NIIN:00D001386
=== Responsible Party ===
Company Name:HACH CO.
Address:100 DAYTON RD
Box:907
City:AMES
State:IA
ZIP:50010-6402
Country:US
Info Phone Num:303-669-3050
Emergency Phone Num:515-232-2533
CAGE:91224
=== Contractor Identification ===
Company Name:HACH CO
Address:5600 LINDBERGH DR
Box:389
City:LOVELAND
State:CO
ZIP:80539
Country:US
Phone:970-669-3050/ 303-623-5716
CAGE:91224

=============  Composition/Information on Ingredients  =============

Ingred Name:LITHIUM HYDROXIDE MONOHYDRATE
CAS:1310-66-3
RTECS #:OJ6307080
Fraction by Wt: <65%
Other REC Limits:NONE SPECIFIED

Ingred Name:POTASSIUM IODIDE
CAS:7681-11-0
RTECS #:TT2975000
Fraction by Wt: <40%
Other REC Limits:NONE SPECIFIED

Ingred Name:SODIUM AZIDE  (SARA III)
CAS:26628-22-8
RTECS #:VY8050000
Fraction by Wt: <5%
Other REC Limits:100 PPB
OSHA PEL:S, C 0.1 PPM(HN3)
ACGIH TLV:C 0.11 PPM; 9394
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:ORAL LD50 (RAT) IS 340MG/KG
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: PRODUCT IS CORROSIVE TO SKIN,
    EYES AND RESPIRATORY TRACT. HARMFUL IF SWALLOWED, MAY CAUSE CNS
    EFFECTS. CHRONIC: DERMATITIS, IRRITATION OF MUCOUS MEMBRANES, CNS
    EFFECTS.
Explanation of Carcinogenicity:MFR LISTS AS "POTENTIAL CARCINOGEN".
Effects of Overexposure:CAUSES BURNING, DIZZINESS, NAUSEA, CENTRAL
    NERVOUS SYSTEM DEPRESSION, COMA, DEATH. CHRONIC IODINE EXPOSURE MAY
    CAUSE SKIN RASH, RUNNY NOSE.
Medical Cond Aggravated by Exposure:RESPIRATORY & SKIN DISORDERS.
    PRODUCT MAY ALSO LOWER BLOOD PRESSURE.

=======================  First Aid Measures  =======================

First Aid:EYES/SKIN: IMMEDIATELY FLUSH WITH WATER FOR 15 MINUTES.
    REMOVE CONTAMINATED CLOTHING. CALL A PHYSICIAN. INGESTION: IF
    CONSCIOUS, GIVE LARGE AMOUNTS OF WATER AND AT LEAST 1 OZ. OF
    VINEGAR MIXED WITH WA TER. GET MEDICAL IMMEDIATE ATTENTION.
    INHALED: REMOVE TO FRESH AIR. GIVE ARTIFICIAL RESPIRATION IF
    BREATHING STOPPED. GET IMMEDIATE MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point:NONFLAMMABLE
Extinguishing Media:MEDIA APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
    FULL PROTECTIVE GEAR.
Unusual Fire/Explosion Hazard:MAY EMIT TOXIC FUMES OF IODINE AND IODINE
    COMPOUNDS IN FIRE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:PLACE IN A BEAKER, DILUTE WITH WATER,
    NEUTRALIZE WITH 6M HYDROCHLORIC ACID AND FLUSH DOWN DRAIN WITH
    EXCESS OF WATER.
Neutralizing Agent:HYDROCHLORIC ACID OR ACETIC ACID

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN COOL, DRY AREA AWAY FROM
    INCOMPATIBLE MATERIALS. KEEP TIGHTLY CLOSED.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE SPECIFIED BY MANUFACTURER. HMIS: IF
    ENGINEERING CONTROLS FAIL OR NON-ROUTINE USE OR EMERGENCY OCCURS;
    USE NIOSH/MSHA APPROVED RESPIRATOR. USE IAW 29 CFR 1910.134 AND
    RESPIRATOR
Ventilation:USE FUME HOOD TO MAINTAIN EXPOSURE BELOW REGULATORY LIMITS.
Protective Gloves:RUBBER
Eye Protection:SAFETY GLASSES
Other Protective Equipment:EYE WASH STATION & SAFETY SHOWER.
Work Hygienic Practices:WASH HANDS AFTER USE AND BEFORE EATING,
    DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

HCC:C2
Melt/Freeze Pt:M.P/F.P Text:230F,110C
Spec Gravity:1.94 (WATER=1)
Solubility in Water:APPRECIABLE
Appearance and Odor:WHITE CRYSTALLINE SOLID; NO DISTINCTIVE ODOR, PH OF
    5% SOLN=12.6
Corrosion Rate:AL 0.248

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG MINERAL ACIDS.
Stability Condition to Avoid:EXPOSURE TO HEAT OR FLAMES, EXCESS
    MOISTURE; CONTACT WITH STRONG MINERAL ACIDS, STRONG OXIDIZING
    AGENTS.
Hazardous Decomposition Products:FUMES OF IODINE AND IODINE COMPOUNDS

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
    FEDERAL REGULATIONS. EPA WASTE NUMBER P105 MAY APPLY.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.