XEROX CORP -- 13R7, 1065/4235/5016/5018/5021/5026/5028/ (SUPDAT) -- 6850-00N023523
=====================  Product Identification  =====================

Product ID:13R7, 1065/4235/5016/5018/5021/5026/5028/ (SUPDAT)
MSDS Date:09/09/1997
FSC:6850
NIIN:00N023523
=== Responsible Party ===
Company Name:XEROX CORP
Address:100 CLINTON AVE S
City:ROCHESTER
State:NY
ZIP:14644
Country:US
Info Phone Num:800-828-6571
Emergency Phone Num:716-422-2177; 716-422-1230
CAGE:0E6G9
=== Contractor Identification ===
Company Name:XEROX CORP
Address:300 MAIN ST NO 27C
City:EAST ROCHESTER
State:NY
ZIP:14645
Country:US
Phone:800-828-6571; 800-351-2024
CAGE:0E6G9
Company Name:XEROX CORPORATION
Address:100 CLINTON AVE SOUTH
Box:City:ROCHESTER
State:NY
ZIP:14644-1877
Country:US
Phone:800-828-6571/716-422-2177
CAGE:26921

=============  Composition/Information on Ingredients  =============

Ingred Name:IRON; (STEEL POWDER)
CAS:7439-89-6
RTECS #:NO4565500
Fraction by Wt: >94%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:BUTADIENE-STYRENE POLYMER (RUBBER); (STYRENE/BUTADIENE
    COPOLYMER)
CAS:9003-55-8
RTECS #:WL6478000
Fraction by Wt: <3.75-4%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:IRON (III) OXIDE; (IRON OXIDE)
CAS:1309-37-1
RTECS #:NO7400000
Fraction by Wt: <0.75-1%
OSHA PEL:10 MG/M3 (FE)
ACGIH TLV:5 MG/M3 FUME (FE)

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:LD50:(ORAL,RAT) >10 G/KG.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:MINIMAL RESPIRATORY TRACT IRRITATION
    MAY OCCUR AS WITH EXPOSURE TO LARGE AMOUNTS OF ANY NON-TOXIC DUST.
    THE RESULTS FROM A XEROX SPONSORED CHRONIC TONER INHAL STUDY,
    DEMONSTRATED NO LUNG CHANGE IN RAT S FOR LOWEST (1 MG/M3) EXPOSURE
    LEVEL (I.E. LEVEL MOST RELEVANT TO POTENTIAL HUMAN EXPOSURE). A
    VERY SLIGHT DEGREE OF FIBROSIS WAS NOTED IN 25% OF ANIMALS AT
    MIDDLE (4 MG/M3) EXPOSURE LEVEL, WHILE SLI GHT DEGREE OF FIBROSIS
    WAS NOTED IN ALL ANIMALS AT HIGHEST (16 MG/M3) EXPOSURE LEVEL.
    THESE FINDINGS ARE ATTRIBUTED TO "LUNG OVERLOADING", A GENERIC
    RESPONSE TO EXCESSIVE AMOUNTS OF ANY DUST RETAINED	IN LUNGS FOR
    PROLONGED (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HEALTH HAZARDS: PERIOD. THIS STUDY WAS
    CONDUCTED USING A SPECIAL TEST TONER TO COMPLY WITH EPA TESTING
    PROTOCOL. THE TEST TONER WAS TEN TIMES MORE RESPIRABLE THAN
    COMMERCIALLY AVAILABLE XEROX TONER AN D WOULD NOT BE FUNCTIONALLY
    SUITABLE FOR XEROX EQUIPMENT.
Medical Cond Aggravated by Exposure:NONE WHEN USED AS DESCRIBED BY
    PRODUCT LITERATURE.

=======================  First Aid Measures  =======================

First Aid:EYES:FLUSH W/WATER FOR AT LEAST 15 MINUTES. SKIN:WASH W/SOAP
    & WATER. INHAL:REMOVE FROM EXPOSURE. INGEST:DILUTE STOMACH CONTENTS
    W/SEVERAL GLASSES OF WATER.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:WATER, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT . AVOID INHALATION OF SMOKE.
Unusual Fire/Explosion Hazard:NONE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:IF SPILLED, SWEEP UP OR VACUUM.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:NONE.
Other Precautions:AVOID PROLONGED INHALATION OF EXCESSIVE DUST.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE REQUIRED WHEN USED AS INTENDED IN XEROX
    PRODUCTS. FOR USE OTHER THAN NORMAL CUSTOMER-OPERATING PROCEDURES
    (SUCH AS IN BULK TONER PROCESSING FACILITIES), NIOSH APPROVED
    RESPIRATORS MAY BE REQUIRED . FOR MORE INFORMATION, CONTACT XEROX.
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
    ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO:5034/5046/5047/5065/
    5321/5328/5334/5335/5365/5624/5626 /5818/5820/
    XC-1875/XC-2675/CLASS IV DEVELOPER.

==================  Physical/Chemical Properties  ==================

Spec Gravity:5 (H*2O=1)
Appearance and Odor:BLACK GRANUAR; FAINT ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:PRODUCTS OF COMBUSTION MAY BE TOXIC.
    AVOID BREATHING SMOKE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL,
    STATE & LOCAL REGULATIONS . WHEN DISPOSED, THIS MATERIAL IS NOT
    HAZARDOUS WASTE ACCORDING TO FEDERAL REGULATION 40 CFR 261.
    HOWEVER, STATE & LOCAL RE QUIREMENTS MAY BE MORE RESTRICTIVE.
    THEREFORE, CONSULTATION WITH APPROPRIATE STATE & LOCAL WASTE DIS
    POSAL AUTHORITIES IS ADVISED.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.